Hydron Module BS/BT indoor split heat pumps provide ducted heating and cooling and hot water assist for up to 40% savings on annual water heating costs. These systems can be paired with a conventional furnace to create a dual-fuel system with optimal energy savings. The BS/BT heat pumps can be used for heating and cooling in small to large homes, storage buildings, agricultural facilities, and more.
Model | BS018 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 21,800 | - |
COOLING EER | 21.10 | - |
HEATING BTU/HR | 18,800 | - |
HEATING COP | 3.90 | - |
Model | BT024 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 26,300 | 21,500 |
COOLING EER | 19.50 | 27.80 |
HEATING BTU/HR | 18,800 | 15,400 |
HEATING COP | 3.90 | 4.30 |
Model | BT036 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 36,900 | 29,300 |
COOLING EER | 19.20 | 28.90 |
HEATING BTU/HR | 27,800 | 22,600 |
HEATING COP | 3.80 | 4.30 |
Model | BT048 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 50,300 | 39,600 |
COOLING EER | 18.40 | 27.10 |
HEATING BTU/HR | 40,700 | 32,100 |
HEATING COP | 3.80 | 4.40 |
Model | BT060 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 61,100 | 48,100 |
COOLING EER | 17.60 | 24.30 |
HEATING BTU/HR | 46,800 | 38,200 |
HEATING COP | 3.80 | 4.20 |
Model | BT072 | |
---|---|---|
CAPACITY | Full Load | Part Load |
COOLING BTU/HR | 67,200 | 54,900 |
COOLING EER | 15.80 | 21.10 |
HEATING BTU/HR | 57,300 | 47,700 |
HEATING COP | 3.40 | 3.80 |